Mounting the stove sensor FI with overtemperature protector
Mount the stove sensor with overtemperature protector FI in the sauna cabin about 15 cm below the ceiling and above
the heating system, or in accordance with specifications of the cabin manufacturer.
The stove sensor with overtemperature protector can only be connected with the attached 150°C temperature-resistant
connecting line.
On the outside of the sauna cabin the temperature-resistant connecting line can be extended with customary lines.
CAUTION - Double insulation is required:
Run the stove sensor line separate to other power cables in the connection range for extra-low voltage of the control.
Protect single insulated lines with a pipe (double insulation).
1. Run four-pin line 5 to mounting site of stove sensor 4 at the cabin wall and fix in position with wiring clips.
2. Separate two half shells 1 of the stove sensor 4 and clamp to four terminal connectors of the temperature-resistant
connection line according to the circuit diagram.
3. Insert round adaptor plate 2 with the connection cross-wise in the half shells 1, close half shells 1 and tighten with
the two recessed head screws 3 which are 9 mm in length.
Check if the stove sensor 4 is safely locked.
4. Perform tests according to the chapter on "Tests".
5. Bolt stove sensor 4 to the cabin wall in alignment with the heater, keep a distance of 15 cm to the ceiling, or mount
in accordance with specifications of the cabin manufacturer, using two wood screws 6.
3
Mounting the bench sensor FII
The bench sensor is mounted in the sauna cabin about 15 cm below the ceiling and opposite of the heating system.
The bench sensor can only be connected with the attached 150°C temperature-resistant connecting line.
CAUTION - Double insulation is required:
Run the bench sensor line separate to other power cables in the connection range for extra-low voltage of the control.
Protect single insulated lines with a pipe (double insulation).
1. Run two-pin line 5 to mounting site of bench sensor 4 at the cabin wall and fix in position with wiring clips.
2. Separate two half shells 1 of the bench sensor 4 and clamp to four terminal connectors of the 150°C temperature-
resistant connection line according to the circuit diagram.
3. Insert round adaptor plate 2 with the connection cross-wise in the half shells 1, close half shells 1 and tighten
with the two recessed head screws 3 which are 9 mm in length.
Check if the bench sensor 4 is safely locked.
4. Perform tests according to the chapter on "Tests".
5. Bolt bench sensor 4 to the cabin wall opposite of the heating system, in the middle ot the bench keeping a di-
stance of 15 cm to the ceiling, using two wood screws 6.