Environmental conditions:
Storage temperature:
Ambient temperature:
-10 °C to + 40 °C
Air humidity:
max. 95 %
Minimum temperature stability of the connecting
lines:
Heating system, lighting circuits, stove and bench lines are heat-resistant to at least 150°C .
Maximum lengths of lines:
Stove sensor F I:
Bench sensor FII:
Fan connection:
Control:
Switching voltage / three-phase 3N:
Frequency:
Switching capacity / heating AC 1:
Switched current each phase / heating AC 1: 13 A
Switching capacity / steam generator AC 1:
Switching capacity / steam generator AC 1:
Nominal voltage:
Min. / max. pick-up capacity:
Degree of protection (splash-proof):
Connection to the main circuit as permanent wiring (non-detachable connection).
Steam generation:
On/ Off time:
approx. 200 s
Min. / max. inrush impulse:
Light:
AC1 switched current:
Switching capacity:
Fan:
Switching capacity:
WE DO IT FIRST.
Instructions for installation and use
-25 °C to + 70 °C
4.5 m
4.5 m
10 m
400 V
50 Hz
3 x 3 kW
3 kW
13 A
230 V
4,3/ 6,3 VA
IP X4
approx. 10 / 200 s
1 A
max. 230W
max. 100W

Technical Data

P. 15/20