4
Error messages
4.1 Displayed error messages 3:
An error message signals an electrical defect of the system.
The control is no longer ready-to-operate:
1. Write down the error message.
2. Switch off the main fuses of the control in
the fuse box.
3. Contact customer service.
4. Mark the control as being defective.
Using the following display error messages 3 you can inform customer service of possible errors / defects.
The error messages mean:
E-F1: short in line / break in
line/ stove sensor FI defective.
E-F2: short in line / break in
line / bench sensor FII defective.
E- 12: break in line or defective
overtemperature protector.
E-P I: damage of the potentiometer 4 for
temperature setting.
E-P 2: damage of the potentiometer 6 for
fan adjustment.
E-P 3: damage of the potentiometer 7 for
steam adjustment.
4.2
Red signal lamp 2 flashes:
Automatically, the control will turn off the heater if the overtemperature protector has responded.
The control is no longer ready-to-operate:
1. Shut off the main fuses of the control
in the fuse box.
2. Contact customer service.
3. Mark the control as being defective.