7.

Technical data

Item No.
Conforms to
Smoke detection
Power supply
"Low battery" error message
"Low battery" warning
Operational battery life
Dimensions (diameter x height)
Environmental conditions
Operating temperature
Max. humidity
Environmental class
Protection class
Security level
Radio frequency
Wireless transmission power
Wireless range
HF immunity
Signals
Volume
Sound frequency
Optical display
Tamper surveillance
Supervision monitoring
Weight
EN
FURM50000
EN 14604: 2005+corr:2008
Optical using (scattered light principle)
4.5 V DC, 3 AA alkaline batteries
Replacement batteries: ABUS recommend
Duracell MN1500, Eveready Energizer E91
< 3.2 V
Approx. 30 days before discharge
Approx. 2 years
122 mm x 50 mm (Ø x H)
Only approved for indoor use
-10 °C - +65 °C
Average relative humidity approx. 75% – non-
condensing
II (EN 50131-1 + A1:2009)
IP 20
2 (EN 50131-1 + A1:2009)
868.6625 MHz
10mW
Approx. 30m indoors (depending on
environmental factors)
10 V/m (EN 50130-4:2011)
Acoustic (Piezo) and visual (LED)
Min. 85 dB(A) @ 3 m
2.7 kHz
LED
No
Yes – approx. every 4 minutes
227,8 g net