Fix the mounting plate in place
Attach the detector on to the mounting plate.
13.

Use

During normal operation the detector is silent. When the activity LED is activated (see chapter 10.3 LED
display), it flashes once every 60 seconds.
If smoke is present in the atmosphere, then it can take up to 9 seconds before the device detects the
smoke, goes into alarm status and activates the sounder. The detector transmits a radio signal to the
receiver for every alarm.
If smoke is detected, a loud alarm sounds.
The alarm continues sounding as long as there is smoke in the smoke chamber.
The alarm is only switched off when there is no more smoke in the smoke chamber.
If an alarm stops, always check carefully that no fire is present.
If internal monitoring of the detector reveals an error, then the sounder will beep once every ten seconds,
the activity LED will flash once per second, and the device transmits a radio signal to the receiver.
Remove the old batteries, wait for 30 seconds and insert new batteries. Check, that the activity LED
functions properly.
If, after the batteries are replaced, the sounder continues to beep once every 10 seconds, then the
device has an error. If the device is still under warranty contact the supplier.

13.1 Silencing the alarm

In order to silence the sounder on the smoke alarm device, briefly press the test button once (see Fig 3).
The detector remains silent for six minutes and then reverts back to normal mode. (If you conduct an
alarm test during these six minutes, then the detector reverts back to normal mode after the test.)