Functional principle and features

Scope of delivery

ABUS smoke alarm device including batteries
User manual
Installation material

Technical data

Power supply
Smoke detection
Heat detection
Power consumption
Operating temperature
Humidity
Sound pressure
Alarm muting
Detection range
Installation location
Radio frequency
2 x 1.5 V alkaline batteries
(replaceable)
Photoelectric reflection
54°C–70°C
<4 µA (standby) || <40 mA (alarm)
0 to 40°C
10% to 93% (non-condensing)
> 85 dB (A)@3 m
< 10 minutes
Max. 40 m² within a room
Ceiling (only in interior spaces)
868.3 MHz