Fig. 12: Filter replacement – Removing the filter element
Item
Description
1
Filter element
2
Gasket ring
Tab. 16: Filter replacement – Removing the filter element
Changing the filter element:
1. Switch the product off at the device switch.
2. Prevent unintentional restarting by disconnecting the mains plug.
3. Remove the new filter element from the box and remove the sealing
cap (item 3). Ensure the sealing ring (item 2) is not damaged in the
process.
4. Gently lift the saturated filter element (item 1) and carefully pull it out of
the product (arrows A + B).
5. Seal the saturated filter element with the sealing cap (item 3) of the new
filter element to make it airtight. Dispose of the saturated filter element
in accordance with current regulations.
1502818-03
Item
Description
3
Sealing cap
4
Mounting frame