Technical Data - Artidor AR-021 Mode D'emploi

Détecteur de mouvement antidéflagrant ex ii 3gd
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

is explosion-safe and certified on the basis of Group II Category 3GD of the ATEX Directive it
is suitable for use in the following types of zones in explosion hazardous areas:
for combustible gases, vapors and mist: zone 2
for combustible fibers and dust: zone 22
5.

Technical Data

Explosion safety category:
Protection against ignition:
Conformity:
Standards applied:
Sensor:
Range:
Registration angle:
Dimmer setting:
Preset time:
Supply voltage:
Output contacts:
Rated current 250 V AC:
Rated current 24 V DC:
Breaking capacity max:
Limited making current:
Electrical connection:
Material:
Entries:
Ingress protection level:
Bracket:
Ambient temperature:
Housing dimensions:
Weight:
Installation manual AR-021 explosion-safe motion sensor
II 3GD
Ex nR IIC T6 Gc, Ex tc IIIC T80˚C Dc
European Directive 2014/34/EU (ATEX) and
2014/30/EU (EMC)
EN 60079-0:2018, EN 60079-15:2010 and
EN 60079-31:2014
5.8 GHz radar currents, 1 mW transmission capacity
1 – 8 m, adjustable
360° with 140° opening angle
3 – 3,000 Lux
10 seconds - 12 minutes
230 VAC, 50 Hz
1. Switched 230 V AC supply (L', N2)
2. Potential free contact (1, 2)
16 A continuous
2 A (for potential free contacts 1, 2)
4,000 VA
30 A, 250 V AC (max 4s, duty cycle 10%)
Connection terminals 8 x 2.5 mm2
Housing: die cast aluminum, RAL 7015, slate gray,
polyamide frame with impact resistant safety glass
M20 cable gland (2x) suitable for cables from 6 – 14 mm
in diameter
IP66 according to EN 60529
Stainless steel 316L mounting bracket, mounting holes
Ø6.5 (4x), mutual distance 60 x 60 mm
-20 °C to +50 °C
160 x 80 x 128 mm (incl. mounting bracket)
1,340 grams (incl. mounting bracket)
E
04-2022
7 / 44