The motion sensor complies with the European Directives for EMC and ATEX and implicit to
the Low Voltage Directive. With regard to explosion safety the motion sensor has been
E
designed and manufactured on the basis of the essential health and safety requirements of
European Directive 2014/34/EU (ATEX 114) relating to Group II Category 3GD. Harmonized
European construction standards have been applied fulfilling the essential requirements of
the directives.
Example of an AR-021 motion sensor label.
7.
Installation instructions
•
Installation of explosion-safe equipment such as this product must be carried out by
personnel specially trained and qualified to do this, following the relevant requirements
of the installation standard EN 60079-14.
•
For the installation and use of this product the relevant safety regulations and also the
generally recognized latest state of the technology apply.
•
During assembly, care must be taken that the framework, screws and surface are strong
enough to take the weight of the motion sensor.
•
Isolate power from the electrical supply cable prior to installation.
•
Install the connection cable and make sure that it is protected from mechanical and
chemical influences.
•
Connect the end of the cable in a proper way to an external connection box and ensure
this is done professionally. The connection box is not supplied. Use a connection box
that it is suitably protected for the (explosion hazard) classification of the surroundings in
which it will be used.
Installation manual AR-021 explosion-safe motion sensor