Operating Instructions - Artidor AR-021 Mode D'emploi

Détecteur de mouvement antidéflagrant ex ii 3gd
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The motion sensor offers 8 connection terminals:
Power in:
L
230 VAC phase
N1 Neutral
PE Earth
8.

Operating instructions

All regulators and pushbuttons are only accessible when the housing is open. The opened
device is not explosion-safe! If an explosion hazard cannot be excluded, undertake
adjustments when the device is switched off only. Before switching on the device, close
housing correctly!
Mechanical alignment: the detection area is approximately spherical. The range increases
with the speed, size and conductivity of the object. The device should aim at approximately
half the height of the object (1m for adults) in the required triggering distance.
Initial values for the regulators:
Range at right stop = min. responsivity (range approx. 1m)
Switch-off delay at right stop = shortest time (approx. 10s)
Installation manual AR-021 explosion-safe motion sensor
Output:
L'
230 VAC phase – switched 1 Connection 1
N2 Neutral (connected to N1) 2 Connection 2
PE Earth
Potential free
contact:
E
04-2022
9 / 44