EB TECHNOLOGY START-S6XL BLOCK Notice D'emploi page 43

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

START-S6XL BLOCK
8.2
Time learning: ADVANCED SYSTEM
1
2
ON
1
1
2
3
4
5
6
1
2
>
TIMES
1
3
>
TIMES
S. DOWN
1
4
>
TIMES
STOP
4 a
1
5
>
TIMES
6
1
>
TIMES
6 a
1
7
>
TIMES
8
1
>
TIMES
S. DOWN
The gate is in CLOSED position
CTS
Put and leave in ON the DIP 10A
7
8
9
10
2
* Push the button TIMES
Push the button TIMES (or START)
2
... If the slowing down is activated
trimmer see. Slow down ...
Push the TIMES button (or START)
2
(if the opening limit switches of motor
no.1 is not available).
... If the limit switch is available
wait until the fi rst motor stops
Push the TIMES button (or START)
2
if the slowing down is activated
(trimmer V. Slow down) ...
S. DOWN
Push the button TIMES (or START)
(if the opening limit switches motor
2
no. 2 is not available)
STOP
... If the limit switch is available wait
until motor no. 2 stops
Let the required pause time run...
2
Push the TIMES button (or START)
Push the TIMES button (or START)
2
if the slowing down is activated
(trimmer see Slow down)
-19-
Technical manual
The gate is in closed position
The fi rst motor OPENS
The fi rst motor slows down
when opening
Motor no.1 stops,
then motor no. 2 OPENS
Motor no.1 stops,
then motor no. 2 OPENS
The second motor slows down
when opening
The second motor stops,
the counting of the pause
time starts
2° motor stops, the counting
of the pause time starts
The second motor CLOSES
The second motor slows down
when closing

Publicité