EB TECHNOLOGY START-S6XL BLOCK Notice D'emploi page 25

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Single phase for 230 Vac 2 motors
• Universal control unit for 1 or 2 motors
• 433 MHz radio receiver included
• Self programming
START-S6XL BLOCK
230 Vac - Neutral
Not used
230 Vac - Phase
Signal light
Signal light
Motor 1 COMMON
Motor 1 OPEN
Motor 1 CLOSE
Motor 2 COMMON
Motor 2 OPEN
Motor 2 CLOSE
LSC Mot 2
LSO Mot 2
LSC Mot 1
LSO Mot 1
FOTO A closing photocell
START
out 24 Vac
out 24 Vac
elect. lock
STOP
PEDESTRIAN
FOTO B always working
Common contacts
+ Antenna
Light / Lamp
Light / Lamp
Interblock / Test
Interblock / Test
12Vac / el. lock
out + 24 Vdc
- 24 Vdc / Common
Safety edge 8K2
Safety edge 8K2
-1-
-2-
-3-
-4-
-5-
-6-
-7-
-8-
-9-
-10-
-11-
-12-
-13-
-14-
-15-
-16-
-17-
-18-
-19-
-20-
-21-
-22-
-23-
-24-
-25-
-26-
-27-
-28-
-29-
-30-
-31-
-32-
-33-
JP2 closed
-34-
to disable the input
!
Complete Operating
Guide
Lamp or courtesy light
230Vac
COM
MOT 1
OP
CL
M
C
COM
CL
OP
M
MOT 2
C
N.C.
N.O.
N.O.
12 Vac Electrical lock
(in case of 24Vac connect to the
terminal board no.20 and 18)
*
Connect this point to the terminal board
no. 28 for the photo-test, otherwise
connect it to the terminal board no. 19
Radio Receiver
*
*
RoHS
C O M P L I A N T
2002/95/EC