4.13
Connection of the PHOTOCELLS A (only in closing mode) 24 Vac
15
16 17
18
Power supply
RX Photocell
Receiver photocell.
N.C. contact
4.14
Connection of the PHOTOCELLS A 24 Vac with phototest
15
16 17
18
19
Power supply
RX Photocell
The TEST on the photocells can only ensures the correct working of the automation if said photocells are
regularly working. The control board will perform a test before every opening. In case of malfunction of the
photocells the control board will turn on the signal light for 5 seconds and will not allow the automation.
To activate the TEST function read carefully and follow the instructions in chapter no. 9
19
20
21
22
23
20
21
22
23
Receiver photocell.
N.C. contact
24
25
Power supply
TX photocell
28
24
25
Power supply
TX photocell
-11-
The contact of the photocell's
receiver must be:
- clean (isolated from the po-
wer supply voltage)
- type N.C.
(normally closed)
If you are using several sets of
photocells the connection must
be done in series.
If the input PHOTO A is
not used put the
DIP 5 B in ON mode
The contact of the photo-
29
30
31
cell's receiver must be:
- clean (isolated from the
power supply voltage)
- type N.C.
(normally closed)
Technical manual