Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Safety System ISK 76-21

Technical data

Supply voltage
Power consumption
Approval
- see notes test signal -
Category 2 according EN 4-1
Safety device according EN 1278
Connection resistance, safety contact edges
R
8,2 kΩ
A
R
> 20 kΩ
AO
R
< 2, kΩ lower switching value
AU
Relay stages
max. switching voltage
max. switching current
mechanical lifetime
Switching times
Reaction time
Release time
Test Input
Input voltage
Enclosure
ABS-plastic housing
Enclosure dimensions
Dimensions with cable glands
Protection class
Weight
Temperature range -20°C to +°C
Cable cross section
0,7-1, mm
2
All external voltages connected to the controller has to be safe sepa-
rated votages!
24
U
24V AC/DC ±10%
E
P
<1,2 VA
max
upper switching value
30 V ~ / 30 V -
2 A ~
/ 2 A -

activations
7
< 20 ms
100 ms
U
< 28 V AC/DC
Test
HxBxT 120 x 80 x 6 mm
HxBxT 140 x 80 x 6 mm
IP6
with cable glands
360 g
Single or fine-strand line
Certificate No.: 78/780/551696
Technical Report No.: 04/YTT551696
I
≤ 4 mA
E

Publicité

Table des Matières
loading

Table des Matières