12
Separated buttons function .
To convert the input START into an input of only CLOSIN G:
Cut off power supply, keep pressed buttons SET and BREAK and give power back at the same time until led DL3 will flash.
To convert the input PED into an input of only OPEN ING:
Cut off power supply, keep pressed buttons WORK, SET and BREAK and give power back at the same time until led DL3 will flash .
Restore the inputs as SEQUEN TIAL/STANDARD input:
To restore the input START: cut off power supply, keep pressed buttons SET and WORK and give power back at the same time unti l
led DL3 will flash.
To restore the input PED: cut off power supply, keep pressed buttons BREAK and WORK and give power back at the same time until
led DL3 will flash.
NOTICE: normally the control panel is always delivered with the inputs START and PED as SEQUENTIAL/STANDARD inputs from the
factory.
13
Dead man with separ ated buttons function.
START only open and PED close only.
As long as the input START is closed, the motor OPENS the door and when START is disengaged, the gate stops.
As long as the input PED is closed the motor CLOSES the door, and when PED is disengaged the gate stops.
To enable this feature follow the procedure below:
1) Do the programming of the door movement (paragraph 7).
2) Cut the power supply on the control panel.
3) Remove the bridge on the input STOP and give power back.
In this way, the control panel with work with the « dead man » function enabled, while keeping the programmed slowing down
spaces on opening\closing
Restore the inputs as SEQUEN TIAL/STANDARD input:
1) Cut off the power.
2) Wire inputs Stop-Common again and give back power.
14
Notice.
1) If during this procedure ther e is a power failure, when the power supply is restored and both limit switches are not engaged,
while giving a command Start or Pedestrian the control panel opens the gate in a slow motion until it finds the limit switch opening.
Then any other movement will be done in an ordinary way keeping the programmed slowing down spaces. Instead, if one of the
limit switches is engaged, when power is restored the gate moves normally.
2) This control panel is provided with an anti -crashing system that detects the obstacles (working ONLY if onboard the operator is
mounted and ENCO DER) . If the control panel detects and obstacles while opening, the gate stops and reverses for about 1 seco nd.
If the control panel detects and obstacles while closing the gate stops and re-open completely (till reaching the limit switch of
opening) .In case there is an automatic re-closing setting on the panel, the gate will try to close for max. 3 times and then will
remain opened waiting for a Start impulse.
3) This control panel has got an input for the safety edge. By the dip 2 on SW2 it is possible to select the type of edge. With the d ip
set in OFF you select a mechanical safety edge working with a switch; it is a NC input if the edge is not engaged (led Costa off) and it
is a NO input when the edge is engaged (led Costa on). With the dip set in ON use a resistive safety edge; if not engaged it has got a
resistance of 8,2K ohm (led Costa off), if engaged it is got a NC input (led Costa on). If you don't use this in put then wire COM and
COSTA (inputs 12 and 13) and set the dip 2 of SW2 in OFF (led COSTA on).