AC/DC VOLTAGE (LESS THAN 1,000 V)
1. Insert the RED test lead into the VΩ jack
test lead into the COM jack
switch
to the AC/DC voltage V
2
to AC measurement. To measure DC, press the 'SEL' button
to toggle between AC and DC modes. The AC or DC icon on the
LCD indicates which mode has been selected. Note 'AC' or 'DC'
on the display.
Black lead Red lead
2. Apply test leads to the circuit to be tested to measure the
voltage. The meter will auto-range to display the measurement
in the most appropriate range.
NOTE: If '–' appears on the LCD, the test leads are being applied to
the circuit in reverse. Change the position of the leads to correct this.
NOTE: When in a voltage setting and the test leads are open,
readings of the order mV may appear on the display. This is noise
and is normal. By touching the test leads together to close the
circuit, the meter will measure zero volts.
AC/DC LoZ VOLTAGE (LESS THAN 600 V)
1. Insert the RED test lead into the VΩ jack
test lead into the COM jack
switch
to the AC/DC LoZ voltage
2
defaults to AC measurement. To measure DC, press the 'SEL'
button
to toggle between AC and DC modes. The AC or DC
9
icon on the LCD indicates which mode has been selected. Note
'AC' or 'DC' on the display.
Black lead Red lead
2. Apply test leads to the circuit to be tested to measure the
voltage. The meter will auto-range to display the measurement
in the most appropriate range.
Do not attempt to measure voltages greater than 600 V
in the LoZ setting.
OPERATING INSTRUCTIONS
4
4
5
, and rotate the Function selector
setting. The meter defaults
5
, and rotate the Function selector
setting. The meter
and the BLACK
and the BLACK
9
11