Cleaning the primary filter (3997C -
3997WC)
When very fine dust is continuously vacuumed without
the vacuum being stopped and the filters cleaned, the
Manufacturer can supply the machine with a filtering system
consisting of four cartridges with capability 3 micron filtration.
The unit is equipped with a fully automatic electropneumatic
device (1) to alternately clean the filtering cartridges (2), which
guarantees continuous service;
Electric panel (3), powered with a 24 V rating, is complete with
cyclic timer to regulate the following times:
time between one cleaning cycle and the next, set on 1
minute;
time between one cartridge (2) cleaning operation and
the next, set from 30 seconds;
opening time of the solenoid valve for backwashed air
exhaust into the cartridge, set at 2 tenths of a second.
The shorter the time, the more energetic the cleaning
action will be.
Pay particular attention not to let the supply pressure
to the filter unit exceed 5 bar (a pressure governor "4"
fig. 7 is installed).
An exceeding pressure will dilate the the pores of the
cartridge, resulting in a reduced filtering capacity.

Emergency stopping

Turn the main switch (Q1, fig. 5) to "0" position.
GB
C31
Figure 7
WARNING!

Emptying the dust container

Before proceeding with these operations, turn off
the vacuum cleaner and remove the plug from the
power socket.
Check the class of the vacuum cleaner.
Before emptying the container it is advisable to clean the filter
(see "Cleaning the main filter" paragraph).
Normal version not suitable for vacuuming hazardous
dust.
Release the dust container (1, Fig. 8), then remove and
empty it.
Make sure that the seal is in perfect condition and
correctly positioned.
Place the container back in position and secure it again.

Plastic bag

A plastic bag (2) can be used to collect dust (see Fig. 8).
In this case, the vacuum cleaner must be equipped with
optional accessories [depressor (3) and grid (4), Fig. 8].
These operations can only be carried out by
trained and qualified personnel who must wear
adequate clothing, in compliance with the laws in
force.
Take care not to raise dust when this operation is
carried out. Wear a P3 protective mask.
In case of dangerous and/or toxic dust, use
different kinds of safety bags.
The bag must only be disposed of by qualified
personnel and in compliance with the laws in
force.