8.7
NIGHT LIGHT™ REPLACEMENT
Your appliance comes equipped with our "Night Light™". The light has been pre-wired and is controlled from
the remote control.
EN
If the lamp or lens needs to be replaced, follow the instructions below.
A.
Unplug the
the left access panel.
B.
Remove the four screws that secure the lens frame. This frame retains
the glass lens. The lamp can now be accessed.
NOTE: Do not handle the lamp (bulb) with bare fi ngers, protect with a clean dry cloth.
The lamp will pull straight out of the socket. Replace with Wolf Steel parts only, as
lamp and lens are special "high temperature" products. When re-installing, ensure
integrity of gasket seal.
THE FIREBOX MUST BE SEALED.
Over-tightening the screws could break the lens. "Light Leakage" from the upper area
may be observed. The holes in the lamp housing are necessary for ventilation and
must not be covered.
8.8

VALVE TRAIN REPLACEMENT

A.
Remove the glass door. See "DOOR REMOVAL AND INSTALLATION" section. Remove the burners,
see "BURNER REMOVAL" section.
B.
Remove the 14 screws holding the valve train in place.
NOTE: A new gasket may be required when reinstalling the valve train assembly. Contact your local
authorized dealer/distributor.
C.
Carefully lift the valve train assembly out far enough to access the manual shut off valve and turn to the
off position. Disconnect the fl ex connector from the valve. You may now lift the valve train out of the