Night Light Replacement (Dx42 Only); Blower Replacement - Napoleon Ascent Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

maintenance
EN

12.4 night light replacement (DX42 only)

Your appliance comes equipped with our Night Light ™. The light has
been pre-wired and can be controlled from the switch on the control
panel.
It is recommended that the Night Light ™ be in the "OFF" position when
the appliance is on.
In the event the lamp or lens needs to be replaced:
Unplug the light from inside the appliance.
Remove the 4 screws that secure the lens frame. This frame retains
the glass lens.
The lamp can now be accessed. It will pull straight out of the socket.
note:
Do not handle the lamp (bulb) with bare fingers as it may be
hot. Use a clean, dry cloth for protection.
Replace the lamp with Wolf Steel parts only, as lamp and lens are
special "high temperature" products.
When re-installing, ensure integrity of gasket seal.
note:
Do not over-tighten the screws, as this could break the lens.
THE FIREBOX MUST BE SEALED.
"Light leakage" from the upper area may be noticed. The holes in the lamp housing are necessary for ventilation
and must not be covered.

12.5 blower replacement

WARNING
!
• Risk of fire and electrical shock!
• Turn off the gas and electrical power before servicing this appliance.
• Use only Wolf Steel approved optional accessories and replacement parts with this appliance. Using
non-listed accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could
result in a safety hazard and will void the warranty and certification.
• Ensure that the fan's power cord is not in contact with any surface of the appliance to prevent electrical
shock or fire damage. Do not run the power cord beneath the appliance.
• The wire harness provided in the blower kit is a universal harness. When installed, ensure that any excess
wire is contained, prevent it from making contact with moving or hot objects.
A.
Turn off the power to the appliance.
B.
Remove the safety barrier.
D.
Unplug the blower from the control board.
E.
Undo the fastener at the left side of the blower mounting plate. The assembly should now slide to the left,
away from the mounting tab.
F.
Disconnect the slip-on connectors at the motor of the blower.
G.
Replace the blower in assembly and reverse previous steps.
H.
Ensure that there are no cables touching the blower.
Drywall dust will penetrate into the blower bearings, causing
irreparable damage. Care must be taken to prevent drywall
dust from coming into contact with the blower or its compart-
ment. Any damage resulting from this condition is not covered
by the warranty policy.
58
W415-2912 / D / 03.25.21
LENS ASSEMBLY
SCREWS
FIREBOX TOP
FRAME
LENS
GASKET

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

D42ntreDx42ntreD42ptreDx42ptre

Table des Matières