8. AIR DISTRIBUTION CIRCUIT
The air distribution system is the all the components that distribute the cooled or heated air in the
conditioned environment. The air distribution system must be designed, to ensure correct air flow in the
environment.
The machine is supplied with the fan with air outlet as in figure 7. The indications relating to the installation
of the various air distribution components are provided below.
Adjustable centrifugal fan: The air conditioner fan can be easily rotated, so you can choose the easiest
position of the air outlet. To facilitate the rotation of the fan, it is recommended to perform it before
positioning the air conditioner in its final location. To rotate the fan, follow the instructions below.
Unscrew the 8 screws of the rear evaporator cover.
Lift the fan holder while paying attention to the fan electric cables.
MACS 7 fan rotation
67