POWER ON/OFF BUTTON
Press the Power On/Off Button to turn the meter on or off. Press and
hold the Power On/Off Button for 2 seconds to turn the meter off.
NOTE: To conserve battery life, the meter will automatically power off
after 10 minutes of inactivity.
MODE BUTTON
Repeated presses of the MODE button will toggle through the
available material types: Drywall, Masonry, Hardwood, Softwood, in
that order. Select the desired material prior to testing.
HOLD BUTTON
Press the HOLD button to lock the current reading. The reading will
remain on the display until the HOLD button is pressed again, or until
the meter automatically powers off.
1. Power on the meter
2. Press the MODE button
on the display.
3. Scan the material by pressing the sensor
to be tested. To ensure the best accuracy, press the back of the
meter against a flat area of the material. The material should
be at least 3/4" (19 mm) thick, which is the depth of the sensor
penetration. If not, consider stacking the material to be measured.
The display will show the percentage of moisture numerically
and segments of the Bar Graph
reference of the level of moisture present in the material per the
chart below.
NOTE: "OL" will appear on the display if the moisture content detected
lies outside the meter's measurement range.
BAR GRAPH MOISTURE INDICATORS
MATERIAL
DRYWALL
MASONRY
HARDWOOD
SOFTWOOD
4

FUNCTION BUTTONS

4
3
5
OPERATING INSTRUCTIONS
4
.
3
until the desired material type appears
GREEN LEDs YELLOW LEDs
0 to 40%
0 to 36%
0 to 14%
0 to 21%
against the material
6
2
will illuminate as a visual
40 to 70%
36 to 63%
14 to 24.5%
21 to 39%
,
A
RED LEDs
70% +
63% +
24.5% +
39% +