Safety Switch TZ...AS1

Inspection and service

WARNING
Danger of severe injuries due to the loss of the
safety function.
If damage or wear is found, the complete switch
f
and actuator assembly must be replaced. Re-
placement of individual parts or assemblies is
not permitted.
Check the device for proper function at regular
f
intervals and after every fault. For informa-
tion about possible time intervals, refer to
EN ISO 14119:2013, section 8.2.
Inspection of the following is necessary to ensure
trouble-free long-term operation:
correct switching function
f
secure mounting of all components
f
damage, heavy contamination, dirt and wear
f
sealing of cable entry
f
loose cable connections or plug connectors.
f
Information: The year of manufacture can be seen
in the bottom, right corner of the type label.
Exclusion of liability and warranty
In case of failure to comply with the conditions for
correct use stated above, or if the safety instruc-
tions are not followed, or if any servicing is not
performed as required, liability will be excluded and
the warranty void.
Notes about
For use and operation as per the requirements
of
(UL), an isolating transformer or a power
supply with secondary overcurrent protection (3 A)
must be used.

EC declaration of conformity

The manufacturer named below herewith declares
that the product fulfills the provisions of the direc-
tive(s) listed below and that the related standards
have been applied.
EUCHNER GmbH + Co. KG
Kohlhammerstr. 16
D-70771 Leinfelden-Echterdingen
Directives applied:
Machinery directive 2006/42/EC
f
Standards applied:
EN 60947-5-1:2004 + Cor.:2005 + A1:2009
f
EN 1088:1995+A2:2008
f
EN 14119:2013
f
The original EC declaration of conformity can also
be found at: www.euchner.de
Service
If service support is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
D-70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
Fax:
+49 711 753316
E‑mail:
support@euchner.de
Internet:
www.euchner.de
9

Technical data

Parameter
Value
Housing material
Anodized die-cast alloy
Degree of protection acc. to
IP67, mating connector inserted
IEC 60529
Mechanical life
1 x 10
operating cycles
6
Ambient temperature
-25 ... +55 °C
Degree of contamination
3 (industrial)
(external, acc. to EN 60947-1)
Installation position
Any
Approach speed, max.
20 m/min
Extraction force (not locked)
30 N
Retention force
10 N
Actuating force, max.
35 N
Actuation frequency
1,200/h
Switching principle SK, ÜK
Positively driven, slow-action
switching contact
Contact material
Silver alloy, gold flashed
Connection
Plug connector M12, 4-pin
Weight
Approx. 0.5 kg
Locking force F
F
= 2,000 N
max
S
Locking force F
F
Zh
max
(F
=
) = 1,500 N
acc. to EN ISO 14119
Zh
1.3
Guard locking solenoid
Solenoid operating voltage
DC 24 V +10%/-15% 10 W
(auxiliary voltage on black
Power supply unit with electrical
AS-Interface cable)
isolation (IEC 60742, PELV)
Solenoid operating current
350 mA
Duty cycle
100%
Connection
M12 plug connector
AS‑Interface data acc. to
EA code: 7
AS-Interface specification 2.1
ID code: B
Operating voltage AS-Interface DC 22.5 ... 31.6 V
Total current consumption,
45 mA
max.
Valid AS-Interface addresses
1 - 31
AS‑Interface inputs
Acc. to AS-Interface Safety at
Work
Door monitoring contact SK
D0, D1
Solenoid monitoring contact
ÜK
D2, D3
AS‑Interface outputs
D0
Guard locking solenoid,
1 = solenoid energized
D1
Red LED, 1 = LED on
D2
Green LED, 1 = LED on
AS-Interface Power LED
Green, AS-Interface Power on
AS-Interface Fault LED
Red, offline phase or address 0"
Reliability values acc. to EN ISO 13849‑1
B
3 x 10
6
10d