EUCHNER TZ AS1 Serie Mode D'emploi page 11

Interrupteur de sécurité
Masquer les pouces Voir aussi pour TZ AS1 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Safety Switch TZ...AS1
Shown:
TZ.R.. actuating head on the right
(actuating head on the left is a mirror image)
31
Power Fault
20
∅5,5
42
With escape release
Figure 3: Dimension drawing for TZ...AS1
+4
b
52
a
23
36
25
GN RD
18
M=1,2Nm (4x)
35
100
110
M=1,2Nm (4x)
M8
Actuated
Length of escape release
Type
TZ...C2381
TZ...C2372
0,3
a Travel without operation:
actuator is in the guide slot, but a
function is not triggered.
b
Switching operation com‑
pleted:
actuator must be inserted to this
point to ensure reliable switching.
The actuator must be withdrawn
at least to point a for switching off.
0,3
5
L1
~ L2
L1
L2
69
75
100
106
11
Auxiliary release with triangular key
(2 triangular keys included)
58
Auxiliary release with pushbutton
91
GN
61
Key to symbols
Guard locking ready for operation
/
Guard locking released
/
Auxiliary release
16,5

Publicité