Assembly / Disassembly COMBIFLUX on motor FEM 3070
> Check before starting the motor if it fits properly on the pump.
> The pin on the motor must be in one of the two bores.
> The clamping levers must both be audibly locked on the motor.
> Never operate the motor without pump (risk of injury due to open
1
Position the motor in such a way that the pin fits into one of the two bores.
2
Press the clamping levers towards the motor until they are both audibly locked.
3
To remove the motor unlock the two clamping levers.
5.
Cleaning after every operation
> Clean the pump by flushing an appropriate cleaning agent.
> Do not use flammable liquids to clean the pump.
> The pump and flexible hose must be compatible with the cleaning agent.
> The pump should not be immersed deeper into the cleaning agent than the
outlet connection.
drive shaft).
Bore
Clamping lever
Clamping lever
Before opening the clamping levers switch off the motor. Wait
until the motor does not turn anymore before removing it.
Original operating instructions motor type FEM 3070