Thermo-Anemometer · testo 405-V1
Instruction manual
An arrow on the protective cap shows the wind
direction in which the instrument was calibrated
and the best readings obtained.
Commissioning
Remove the protective film on the display.
Switching on
Press button once
Segmenttest
Current reading
Changing the parameters
Press button repeatedly:
Velocity
Temperature
Set duct cross-section m
3 Keep On button pressed when switching on.1st
position flashes.
1 Keep On button pressed until desired digit appears.
Wait 2 seconds and the digit will apply. The cursor
then changes to the next position.
2 Repeat the described procedure for all positions.
¬ Multi-purpose clip
Á Holder for positioning
stick in duct.
® Twist ring: The lower
part of the probe stem
can be twisted by 90°.
This allows an optimum
view of the display
¯ Protective cap:
The velocity sensor is
protected by a quick
twist of the bottom of
the probe stem
the
à
protective cap is clo sed.
Should only be left open
for the duration of the
measurement.
° Swivel head. The dis play
can always be read.
Volume
2
Switching off
Keep button pressed for 3 seconds.

Technical data

Type of application: ..................................................Short measurement
Measuring range m/s: ..........................................0 to 5m/s at -20 to 0 °C;
Measuring range m3/h: ................................................ 0 to 99990 m3/h
Measuring range °C: ..........................................................-20 to +50 °C
Resolution:.....................................................................0.01 m/s; 0.1 °C
Accuracy: (system accuracy at calibration temp. +25°C)
Ambient temperature: ........................................................... 0 to +50 °C
Storage temperature: .........................................................-20 to +70 °C
Battery type: ............................................................................... 3 x AAA
Battery lifetime: ...................................................................Approx. 20 h
(approx. 750 measurements lasting 2 minutes each)
Probe stem: ........................................................Ø 0.5 in/0.6 in / Length:
CE guideline.......................................................................... 2014/30/EC
Please read before using instrument
• Observe flow direction
• Adhere to sensor measuring ranges
• Do not exceed maximum storage and operating
temperatures (e.g. protect measuring instrument
from direct sunlight)!
• Inexpert handling cancels your warranty.
• Do not touch the sensor, keep the sensor clean.
Close protective cap after use.
Changing the battery
The battery has to be changed if the
appears in the display during the
measurement.
3 Instrument is switched off.
1 Open battery compartment cover.
2 Remove spent batteries and insert new batteries
(3 x AAA) into the battery compartment. Observe
polarity!
3. Close battery compartment cover.
Auto Off function
If no button has been pressed in approx.5 minu-
tes, the instrument switches itself off
automatically.
0 to 10 m/s at 0 to +50 °C
±(0.1 m/s + 5 % of m.v.) (to 2 m/s);
±(0.3 m/s + 5% of m.v.) (over 2 m/s)
± 0.5 °C