Installation Instructions

Before You Start...
1. Read this manual carefully and completely.
2. aRDa range hoods conform to ETL/CSa
standards. Please check your local building codes
for any additional requirements.
3. The appliance has been manufactured as class
I, therefore ground connection is necessary. a
110/120 V plug is provided. The range hood must
be installed so that the plug is easily accessible.
4. This appliance has been designed for use
in both ducted and recirculating modes. (Kit
Required) Follow the appropriate installation method.

Planning Your Installation

1. Measure the floor to ceiling height. This hood can be installed on walls between
7½" and 8½" tall. If a taller chimney is required, please contact your dealer or visit
www.ardaappliances.com
2. Find the centre point of your opening. Mark a plumb line through this point from
ceiling to your range/cook-top.
3. Check your range/cook-top User Manual for the specified minimun and maximum
distance above your cooking suface. Mark the minimum clearance on the centre line.
Installing a cross brace within the wall at the mounting height is recommended.
4. Decide where the ductwork will run between the hood and the outside. Short,
straight duct runs will provide the most air flow.
5. If a recirculating kit is necessary, you may purchase one through your dealer or by
contacting us at www.ardaappliances.ca
6. Install 110/120 V electric plug within the dimensions of the decorative chimney (a)
- 3 -
2. WALL MOUNTED HOODS
opening
Grounded
Outlet
(a)
Floor to
Ceiling
(B)
Cooking
surface to
bottom of
Center
line of
Grounded outlet box
Grounding Plug
Grounding Pin
hood