9 Servicing and maintenance

9.1 Draining the condensation water

Over time, condensation will collect in the air conditioning unit's tank. If the tank is
full, the unit stops and Ft (= full tank) appears on the display.
Draining the condensation water manually:
>
Remove the plug of the air conditioning unit from the wall socket.
>
Place a suitable container under the lower condensate drain (9, page 8).
>
Remove the drain cap and let all the water drain into the collection vessel.
>
When the water has drained, put the cap back on the condensate drain.
>
You can then put the air conditioner back into operation.
Automatically drain the condensed water continuously:
In dehumidifier mode, the condensed water must be continuously drained to the
outside. The upper condensate drain (10, page 8) is provided for this purpose.
>
Remove the plug of the air conditioning unit from the wall socket.
>
Place a suitable container under the upper condensate drain (10, page 8).
>
Remove the drain cap and attach a suitable hose to the drain connection.
>
The hose should now be directed straight down into the collection vessel. Be
careful not to kink the hose.
>
Put the air conditioner back into operation and activate the dehumidifier
mode.
In cool mode, the upper condensate drain must be closed to ensure efficient
operation.