lectrical connections
• Hobs are delivered with a three-
c o n d u c t o r ( i n c l u d i n g a y e l l o w /
g r e e n e a r t h w i r e ) H05VVF or
H05V2V2F - T90 1mm section cable,
and must be connected to the mains
by the intermediary of CEI 60083
standardised neutral plug, or a single
pole cut-off device with a contact ope-
ning by at least 3mm.
• Connect the wires onto the unit fol-
lowing the colour code (see diagram
opposite).
The protective conductor is connected to the
and therefore must also be connected to an
external earth connection
If the power supply cable is damaged, it must be replaced with a cable or a special
unit available from the manufacturer or his After Sales Service.
The constructor will accept no responsibility for any incidents and possible conse-
quences, should the hob be used without an earth or with a faulty earth.être engagée
en cas d'incident et de leurs conséquences éventuelles.
42
09:02
Page 42
Installing your hob in all simplicity
C
ROSS SECTION OF THE CABLE TO USE
Cable H05V2V2F T-90
H05VVF
Cross section
of conductors in mm²
Fuse
Blue wire
.
220/240 V~ - 50/60 Hz
3 conductors of which
1 is to be earthed
1,5
16A
Black, brown or
red wire
Neutral
(N)
Phase
Earth
Green/yellow wire
earth connection on the hob