Installing your hob in all simplicity

F
itting recommendations
Cut-out
Outside
dimensions above
the work surface
Outside
dimensions below
the work surface.
This appliance should be installed by a
qualified technician / installer.
Prior to installation, ensure that the
local distribution conditions (nature of
the gas and gas pressure) and the
adjustment conditions of the appliance
are compatible.
The adjustment conditions are stated on a
label in the wallet and also on the
packaging.
Since this appliance is not connected to a
combustion products evacuation device, it
must be installed in accordance with current
installation regulations and used in a well-
ventilated place. Particular attention should
be given to the relevant requirements
regarding ventilation.
Disconnect the apparatus before intervention
36
09:02
Page 36
Width
56 cm
60 cm
55 cm
Depth
Depending on
48 cm
51,8 cm
47 cm
On this subject, combustion can take place
only if oxygen from the air is present, so this
air must be constantly renewed and the
combustion products must be evacuated (a
minimum air input of 2 m3/hour per kw of
gas energy is required).
E.g. 60 cm model - 2 gas burners :
Total power :
3.1 + 1.5 = 4.6 kW.
4.6 kW x 2 = 9.2 m3/h minimum airflow.
These hobs in accordance with standard EN
60.335.2.6 against overheating of cupboards
and Class 3 for installation itself (in
accordance with standard EN 30.1.1).
Height
cupboard
5 cm
6,5 cm