USE

INTENDED USE

This product is intended for permanent
installation for pumping water from non-
pressurised sources of water (for example
wells) for domestic and garden purposes in
private households. Fresh water or rainwater
and chlorinated water (pools) can be pumped
with the product. The product must only
be used as it is intended to be used and in
accordance with the technical data and other
instructions in these instructions.
Incorrect/non-intended use
Continuous operation, pumping of drinking
water, salt water, food, contaminated water
or water containing sand or abrasive particles,
corrosive liquids and chemicals, flammable or
explosive liquids, volatile/gaseous liquids and
liquids hotter than 35°C.

ELECTRICAL CONNECTION

The product must be connected to a correctly
earthed power point protected with a residual
current device that has a maximum tripping
current of 30 mA.
Starting
1.
Plug in the plug and start the product.
2.
The pump starts and begins pumping
water.
WARNING!
The inlet tube must be filled with water
before starting the product.
Stopping
1.
Press the OK button. Press the power
switch OK again to switch off the product
when "Pump off" is shown.
2.
Pull out the plug.
3.
Open the tap to relieve the pressure in the
outlet tube.
INSTALLATION AND
COMMISSIONING
1.
Place the product on a level, dry and
stable surface. The installation should be
protected from rain and splashing water.
2.
Fit the suction tube. Seal the connection
with teflon tape, if necessary.
IMPORTANT:
The suction tube should be provided
with a non-return valve to prevent
return flow, which can cause the water
in the product and the suction tube to
empty when the product is not running.
Any leakage will allow air to penetrate
the system, which reduces the pumping
capacity.
The suction tube should be provided
with a pre-filter if the pumped water is
contaminated or turbid, to avoid
damaging the non-return valve and
product.
The suction tube should consist of a
reinforced hose with a 3/4" threaded
connection that is not squeezed by the
intake pressure.
The suction tube should have an
uninterrupted inclination from the pump
to the source of the water. No part of the
suction tube should be higher than the
pump, this can result in pockets of air.
Make sure that the inlet on the suction
tube is always covered with water.
Suction and outlet tubes should be
installed so that the product is not
subjected to mechanical stress.
3.
Connect the outlet tube.
EN