No display.
"dr"
Audible alarm also.
"no" "FL"
Audible alarm also.
"no" "AC"
Audible alarm also.
"dc" "LO"
"FL" "- -"
"LI" "oP"
"AC" "rE"
Audible alarm also.
"AC" "HE"
Audible alarm also.
"Sr"
Audible alarm also.
"C1"
"C2"
"C3"
"C4"
"C5"
Fault Code Meaning
DC voltage is
unavailable tothe
refrigerator control
panel or the
refrigerator is OFF.
The door was open for
more than 2 minutes.
The burner did not ignit
or re-ignite.
AC voltage is
unavailable to the
refrigerator control.
DC voltage to the
refrigerator control
panel is too low.
"dc" "LO"
A flame sensed
present when it should
not be.
The high temperature
limit switch is open.
This is a fault within
the refrigerator
controls.
This is a fault within
the refrigerator
controls.
This is a fault within
the refrigerator
controls.
Fresh food air
thermistor sensed out
of range.
Freezer fin thermistor
sensed out of range.
Freezer air thermistor
sensed out of range.
Exterior fan thermistor
sensed out of range.
Fresh food fin
thermistor sensed out
of range.
Check:
- That the refrigerator is ON.
- That the battery charging equipment of the vehicle is operational.
- That the AC/DC converter is operational (if applicable).
- See your dealer or authorized Norcold Service Center.
Close the door.
Check:
- That the valve of the propane gas tank(s) is open.
- That the propane gas is at the correct pressure.
- That the manual shut off valve of the refrigerator is open.
- That there is no air in the propane gas supply line. See "Removing air from
the propane gas supply lines" section of this manual.
- See your dealer or authorized Norcold Service Center.
Check:
- That the refrigerator is plugged into a serviceable outlet.
- That the fuse or circuit breaker is intact.
- That the vehicle generator is operational (if applicble).
- See your dealer or authorized Norcold Service Center.
Check:
- That the battery charging equipment of the vehicle is operational.
- That the AC/DC converter is operational (if applicable).
- See your dealer or authorized Norcold Service Center.
Shut of the propane gas supply to the refrigerator. This is not owner
serviceable. See your dealer or authorized Norcold Service Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.
This is not owner serviceable. See your dealer or authorized Norcold Service
Center.