AC Power
Power Linking
AC Plug

Replacing The Fuse

DMX Linking
DMX Connection
This product has an auto-ranging power supply that can work with an input voltage
range of 100–240 VAC, 50/60 Hz.
You can link up to 6 Rogue™ R1 Spot products at 120 V, 12 products at 208 V, or
13 products at 230 V. Never exceed this number. Power linking cords can be
purchased separately.
Connection
AC Live
AC Neutral
AC Ground
1. Disconnect this product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
The Rogue™ R1 Spot will work with a DMX controller using a 3- or 5-pin DMX
data connection. A DMX Primer is available from
The Rogue™ R1 Spot uses a 3- or 5-pin DMX data connection for its DMX
personalities: 16CH and 19CH. See the User Manual for information about
connecting and configuring the product for DMX operation.
Wire (U.S.)
Wire (Europe)
Black
White
Green/Yellow
Green/Yellow
3
Screw Color
Brown
Yellow/Brass
Blue
Silver
Green
www.chauvetprofessional.com