AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Connection
AC Live
AC Neutral
AC Ground
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.

Replacing the Fuse

1.
Disconnect this product from power.
2.
Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from the housing.
3.
Remove blown fuse and replace with a good fuse of the same type and rating.
4.
Screw the fuse holder cap back in place and reconnect power.
Mounting
The Ovation SP-300CW comes with an adjustable tripod stand. Before mounting this product, read the

Mounting Diagram

Tilt adjustment
knob
Mounting bracket
Spindle
Ovation SP-300CW QRG Rev. 3
QUICK REFERENCE GUIDE
Wire (U.S.)
Black
White
Green/Yellow
Wire (Europe)
Brown
Blue
Green/Yellow
Spindle bolt
Tripod adjustment knobs
Leg lock pin
Pull pin to telescope leg
for mounting on uneven
Leg lock knob
EN
Screw Color
Yellow/Brass
Silver
Green
Safety
Notes.
surfaces