OPERATING CONDITIONS
®
The HOPPERJET
filters function
under the following operating
conditions:
1) Maximum permitted tempera-
ture:
POSITIVE:
80°C continuous
100°C peak
NEGATIVE:
-20°C
2) Maximum permitted pressure:
POSITIVE:
350mmH
O
2
NEGATIVE:
350mmH
O
2
CHOICE CRITERIA
VERSION WITH ONE OR TWO
SOLENOID VALVES
3
If V ³ 0.15m
use version with
one solenoid valve
3
If V < 0.15m
use version with
two solenoid valves
V = volume of hopper to be de-
dusted
HOPPERJET
®
R01 -
OPERATING AND CONDITIONS
HOPPERJET
®
R01 -
KÄYTTÖRAJOITUKSET
HOPPERJET
®
R01 -
LIMITES D'EMPLOI
®
HOPPERJET
R01 -
LIMITI DI IMPIEGO
KÄYTTÖRAJOITUKSET
®
HOPPERJET
-suodattimet toimi-
vat asianmukaisesti vain seu-
raavia raja-arvoja noudatettaes-
sa:
1) Sallitut lämpötilat:
SUURIN SALLITTU:
80 °C jatkuvassa käytössä
100 °C huippuarvo
PIENIN SALLITTU:
-20 °C
2) Painerajat:
YLÄRAJA:
350 mm H
O
2
ALARAJA:
350 mm H
O
2
VALINTAKRITEERIT
YHDELLÄ TAI KAHDELLA
MAGNEETTIVENTTIILILLÄ
VARUSTETTU VERSIO
3
Jos V ³ 0,15 m
, käytetään yh-
dellä magneettiventtiilillä varus-
tettua versiota.
Jos V < 0,15 m
3
, käytetään kah-
della magneettiventtiilillä varus-
tettua versiota.
V = pölystä puhdistettavan sup-
pilon tilavuus
LIMITES D'EMPLOI
Les filtres HOPPERJET
®
exer-
cent leur foncion d'utilisation
dans le respect des limites d'em-
ploi suivantes.
1) Températures maxi admissi-
bles:
POSITIVE:
80°C en continu
100°C pics
NEGATIVE:
-20°C
2) Pressions maxi admissibles:
POSITIVE:
350mmH
O
2
NEGATIVE:
350mmH
O
2
CRITERES DE CHOIX
VERSION A 1 OU 2 ELECTRO-
VANNES
Si V ≥ 0,15 m
3
utiliser la version à
1 électrovanne
Si V < 0,15 m
3
utiliser la version à
2 électrovanne
V = volume de la trémie à
dépoussiérer
04.01
09.02 /
2
03510.60.M
. 05
LIMITI DI IMPIEGO
I filtri modello HOPPERJET
esercitano la loro funzione d' uso
nel rispetto dei seguenti limiti di
impiego.
1) Temperature max ammissibi-
li:
POSITIVA:
80°C in continuo
100°C di picco
NEGATIVA:
-20°C
2) Pressioni max ammissibili:
POSITIVA:
350mmH
O
2
NEGATIVA:
350mmH
O
2
CRITERI DI SCELTA
VERSIONE 1 O 2 ELETTRO-
VALVOLE
Se V ≥ 0,15 m
3
utilizzare la ver-
sione a 1 elettrovalvola
Se V < 0,15 m
3
utilizzare la ver-
sione a 2 elettrovalvole
V= volume della tramoggia da
depolverare
®