26
The supply of the LK200 can be taken from the reverse-loop area. A direct connection to the
amplifier which supplies this track section is also possible.
Connect terminals "J" and "K" of the terminal pair "IN" to terminals "J" and "K" of the amplifier.
The reverse-loop area (highlighted in grey) that has been isolated on both the entry and the exit
sides is connected to terminals "J" and "K" of the terminal pair "OUT".
Regardless of the track layout, the reverse-loop area (which is the area supplied by the
output of the LK200) must always be so long as to be able to accommodate in its entirety the
longest train operating on the layout!
Advice:
The track section before and after the reverse-loop area must be supplied by the same
amplifier as the reverse-loop area!