8� Operation/maintenance
Weather conditions may affect the
way the motion detector works.
Strong gusts of wind, snow, rain or
hail may cause the light to come
ON when it is not wanted because
the sensor is unable to distinguish
between sudden changes of tem-
perature and sources of heat. The
detector lens may be cleaned with a
damp cloth if it gets dirty (do not use
cleaning agents).
9� EC Declaration of
Conformity
STEINEL Vertrieb GmbH hereby
declares that the IS 140-2 Z-Wave
radio equipment type conforms to Di-
rective 2014/53/EU. The full wording
of the EU Declaration of Conformity
is available for downloading from the
following Internet address:
http://www�steinel�de
10� Warranty
This STEINEL product has been
manufactured with utmost care,
tested for proper operation and
safety and then subjected to random
sample inspection. Steinel guarantees
that it is in perfect condition and
proper working order. The warranty
period is 36 months and starts on
the date of sale to the consumer.
We will remedy defects caused by
material flaws or manufacturing faults.
The warranty will be met by repair or
replacement of defective parts at our
own discretion. The warranty shall not
cover damage to wear parts, damage
or defects caused by improper
treatment or maintenance. Further
consequential damage to other
objects shall be excluded.
Claims under the warranty will only
be accepted if the unit is sent fully
assembled and well-packed with a
brief description of the fault, a receipt
or invoice (date of purchase and
dealer's stamp) to the appropriate
Service Centre.
Service: our Customer Service
Department will repair faults not cov-
ered by warranty or after the warranty
period has expired. Please send the
product well-packed to your nearest
Service Centre.
- 20 -
11� Technical specifications
Dimensions H x W x D
70 × 86 × 95 mm
Mains power supply
230-240 V, 50 Hz
Output
Incandescent lamps, max. 1000 W at 230 V AC
Fluorescent lamp, max. 500 VA at cos  = 0.5,
inductive load at 230 V AC
LED lamps, max. 6 × 58 W, C ≤ 132 μF at 230
V AC *
Sensor technology
Passive infrared
Angle of coverage
140° with sneak-by guard
Reach
max. 14 m (temperature-stabilised) via control dial
Time setting
3 min. factory setting /
1 s to 15 min with the app
Twilight setting
2-2000 lux via control dial and with the app
IP rating
IP54
Temperature range
-20°C to +50°C
Z-Wave wireless range
approx. 100 m (unobstructed line of vision)
Radio frequency band
868 MHz
Transmitter power
≤ 2.5 mW
*1)
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
1)