STEINEL IS 140-2 Z-Wave Mode D'emploi page 25

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Advanced Configuration
For more detailed information, please download the professional instructions from
z-wave�steinel�de.
A� Description of device endpoints:
The functionality of the device is divided to endpoints by their using.
0 = ROOT
To root summarizes whole device function, to root endpoint is mapped all
functionality from the endpoint 1 and most of the endpoints 2 and 3.
Device type = Sensor - Notification
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_VERSION ( v2)
COMMAND_CLASS_FIRMWARE_UPDATE_MD ( v3 )
COMMAND_CLASS_MANUFACTURER_SPECIFIC ( v2 )
COMMAND_CLASS_MULTI_CHANNEL ( v4 )
COMMAND_CLASS_DEVICE_RESET_LOCALLY ( v1 )
COMMAND_CLASS_CONFIGURATION ( v1 )
COMMAND_CLASS_POWERLEVEL ( v1 )
COMMAND_CLASS_NODE_NAMING ( v1 )
COMMAND_CLASS_NOTIFICATION ( v4 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
COMMAND_CLASS_SENSOR_MULTILEVEL ( v4 )
COMMAND_CLASS_SWITCH_BINARY ( v1 )
COMMAND_CLASS_SWITCH_ALL ( v1)
COMMAND_CLASS_APPLICATION_STATUS ( v1 )
Controlled Command Classes:
COMMAND_CLASS_BASIC ( v1 )
Special meaning of BASIC CC:
BASIC CC can activate/temporary deactivate internal motion sensor using for
evaluating the behaviour of the lamp and groups 2 and 3. Events are, however,
still transmitted to the Lifeline, and the device can be controlled via remote motion
sensors. Or can be used for endpoint 3 state (please also follow the configuration
parameter 16).
For parameter 16 = 0 or 255:
Basic Set: mapped to Binary Switch Set of relay endpoint
Basic Get: mapped to Binary Switch Get of relay endpoint
Basic Report: mapped to Binary Switch Report of relay endpoint
For parameter 16 = 1-204:
Basic Set: active (0xFF) /inactive (0x00) sensor function
Basic Get: request sensor status
Basic Report: advertise sensor status
- 48 -
1 = MOTION SENSOR
To endpoint 1 is mapped motion sensor ( PIR ) functionality.
Device type = Sensor - Notification
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_BASIC ( v1 )
COMMAND_CLASS_ASSOCIATION ( v2 )
COMMAND_CLASS_NOTIFICATION ( v4 )
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
Controlled Command Classes:
COMMAND_CLASS_BASIC ( v1 )
Special meaning of BASIC CC:
BASIC CC can activate/temporary deactivate internal motion sensor using for
evaluating the behaviour of the lamp and groups 2 and 3. Events are, however,
still transmitted to the Lifeline, and the device can be controlled via remote motion
sensors (please also follow the configuration parameter 16).
Basic Set: active ( 0xFF ) /inactive ( 0x00 ) sensor function
Basic Get: get sensor activity
Basic Report: sensor activity status
2 = AMBIENT LIGHT SENSOR
To endpoint 2 is mapped ambient light sensor functionality.
Device type = Sensor - Multilevel
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO ( v2 )
COMMAND_CLASS_SENSOR_MULTILEVEL ( v4 )
COMMAND_CLASS_ASSOCIATION (v2)
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION ( v3 )
COMMAND_CLASS_ASSOCIATION_GRP_INFO ( v1 )
Controlled Command Classes:
No
3 = RELAY
To endpoint 3 is mapped basic relay functionality.
Device type = On/Off Power Switch
Supported Command Classes:
COMMAND_CLASS_ZWAVEPLUS_INFO (v2)
COMMAND_CLASS_BASIC (v1)
COMMAND_CLASS_ASSOCIATION (v2)
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION (v3)
COMMAND_CLASS_ASSOCIATION_GRP_INFO (v1)
COMMAND_CLASS_SWITCH_BINARY (v1)
COMMAND_CLASS_SWITCH_ALL (v1)
COMMAND_CLASS_APPLICATION_STATUS (v1)
Controlled Command Classes:
No
- 49 -

Publicité

Table des Matières
loading

Table des Matières