6.1.1 MINIMUM FRAMING DIMENSIONS

FOR TOP EXIT APPLICATIONS: DO NOT BUILD INTO THIS AREA. IT MUST BE LEFT CLEAR TO
PROVIDE ADEQUATE CLEARANCE FOR THE VENT. IN THIS 14" (356MM) WIDE AREA CENTRED
ALONG THE FRONT OF THE APPLIANCE, NO COMBUSTIBLES ARE ALLOWED.
14 1/2"
368mm
36 3/4"
933mm
Combustion protrusions such as mantels and shelves may occur at or after a minimum distance of 2" (25mm) away from
the side of the appliance.
Thereafter, the depth of any protrusions must be equal to or less than the distance from the side of the appliance up to a
depth of 6" (152mm), after which no greater clearance than 6" (152mm) is required. This can be considered a side wall with
no length boundary.
WARNING
!
14"
356mm
3 1/2"
1 1/2"
89mm
38mm
38 3/4"
984mm

STAND-OFF ASSEMBLY

Bend and secure the top stand-off(s) as illustrated:
A
B
OUTSIDE
CHASE
37 3/4" 959mm
14 1/2"
368mm
37 3/4" 959mm
PROTRUSION
35
EN
C
14 1/2"
368mm
INSIDE
CHASE
2" 51mm
4" 102mm
2" 51mm
SIDE
4" 102mm
WALL
6" 152mm
W415-0773 / F / 08.26.13

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Bgd36ntrGd36ptrBgd36ptr