Top Or Rear Exit Vertical Termination - Napoleon GD36NTR Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.10 TOP OR REAR EXIT VERTICAL TERMINATION

Simple venting configurations.
For vent configurations requiring one or more 90° elbows (top exit) or one or more 90° elbows
(rear exit), the following formulas apply:
Formula 1: H
< V
T
T
Formula 2: H
+ V
T
T
Example:
V
= 5 FT (1.5m)
1
V
= 6 FT (1.8m)
2
V
= 10 FT (3.1m)
3
V
= V
+ V
+ V
= 5FT (1.5m) + 6FT (1.8m) + 10FT (3.1m) = 21 FT (6.4m)
T
1
2
3
H
= 8 FT (2.4m)
1
H
= 2.5 FT (0.8m)
2
H
= H
+ H
= 8FT (2.4m) + 2.5FT (0.8m) = 10.5FT (3.2m)
R
1
2
H
= .03 (four 90° elbows - 90°)
O
= .03 (360° - 90°) = 8.1 FT (2.5m)
H
= H
+ H
= 10.5FT (3.2m) + 8.1FT (2.5m) = 18.6FT (5.7m)
T
R
O
H
+ V
= 18.6FT (5.7m) + 21FT (6.4m) = 39.6FT (12.1m)
T
T
Formula 1:
H
18.6 FT (5.7m) < 21 FT (6.4m)
Formula 2:
H
39.6FT (12.1m) < 40 FT (12.2m)
Since both formulas are met, this vent configuration is acceptable.
< 40 feet (12.2m)
< 3.5V
T
T
+ V
< 40 FT (12.2m)
T
T
(H
) < (V
)
T
T
See graph to determine the required vertical rise V
required horizontal run H
40 (12.2)
30 (9.1)
REQUIRED
VERTICAL RISE
IN FEET
20 (6.1)
(METERS)V
T
10 (3.1)
3 (0.9)
0
HORIZONTAL VENT RUN PLUS OFFSET IN FEET
The shaded area within the lines represents acceptable
.
T
5
10
15
(1.5)
(3.1)
(4.6)
(METERS) H
T
values for H
and H
T
T
18.2A
W415-0773 / F / 08.26.13
21
EN
for the
T
20
(6.1)

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Bgd36ntrGd36ptrBgd36ptr

Table des Matières