Wall And Ceiling Protection; Gd36 Horizontal Installation - Napoleon GD36NTR Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.1

WALL AND CEILING PROTECTION

DO NOT FILL THE SPACE BETWEEN THE VENT PIPE AND ENCLOSURE WITH ANY TYPE OF
MATERIAL. DO NOT PACK INSULATION OR COMBUSTIBLES BETWEEN CEILING FIRESTOPS.
ALWAYS MAINTAIN SPECIFIED CLEARANCES AROUND VENTING AND FIRESTOP SYSTEMS.
INSTALL WALL SHIELDS AND FIRESTOPS AS SPECIFIED. FAILURE TO KEEP INSULATION OR
For clearances to combustible materials from the vent pipe, see "FRAMING" section.

5.4.1 GD36 HORIZONTAL INSTALLATION

THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP.
TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE
A. Assemble the two halves of the vent sleeve by aligning the holes that
come together to make a rectangular shape (lip to the outside). Secure
using 6 of the screws supplied in the manual baggie.
NOTE: Screws not required in two blind holes.
B. Fit the fi restop spacer into one end of the vent sleeve and secure
through the aligned holes on the top, bottom, and sides with the
remaining 5 screws supplied.
This application occurs when venting through an exterior wall.
Having determined the air terminal location, cut and frame
a hole in the exterior wall 9 7/8" (250.8mm) wide by 11
3/8" (288.9mm) high to accommodate the fi restop sleeve
assembly.
The length of the vent shield may be cut shorter for
combustible walls that are less than 8 1/2" (215.9mm)
thick but the vent shield must extend
the full depth of the combustible wall.
C. Insert the fi restop sleeve assembly into the wall,
mark the wall depth and trim the vent sleeve to
suit. The screws that secure the vent sleeve may
need to be repositioned to ensure a rigid assembly is
maintained.
D. Apply a bead of caulking (not supplied) to the inside
surface of the fi restop fl ange and secure the assembly
to the wall. (Ensure that the rectangular shaped
assembly is installed to maintain 2" (50.8mm) from the
top of the vent).
E. Once the vent pipe is installed in it's fi nal position, apply
high temperature sealant W573-0002 (not supplied)
between the pipe and the fi restop.
OTHER MATERIALS AWAY FROM VENT PIPE MAY CAUSE FIRE.
RETURN FLANGE OF THE MOUNTING PLATE.
WARNING
!
WARNING
!
2" (50.8mm)
1" (25.4mm)
CAULKING
FLANGE
FIRESTOP
SLEEVE
ASSEMBLY
DRAFT
BLIND
HOLES
VENT
VENT
SHIELD
SLEEVE
TOP
FIRESTOP
SPACER
1" (25.4mm)
11
3/8
" (288.9mm)
9
7/8
" (250.8mm)
DETERMINE
THE CORRECT
HEIGHT
20.1B
W415-0773 / F / 08.26.13
25
EN