10 Troubleshooting

Risk of injury and machine damage when handled by unauthorized persons
Incorrect repair work and changes of the product may lead to significant injuries and machine damage.
The product warranty will be rendered invalid if the unit is handled by unauthorized persons.
• Operating, maintenance, cleaning and repair work may only be carried out by qualified personnel
Please observe the attached document Warranty. Please consult your dealer or the manufacturer in case of
doubt and problems.
NOTICE
• Please observe the operating instructions of the welding components, coolant recirculator iROB Cool
Fault
Cause
• No mains voltage on supply socket
• Plug or supply cable defective
The system cannot be
switched on (green
• Mains fuse blown
LED off)
• Main switch defective
• No start signal
No output power (no
welding takes place)
• System overheated
(Overtemperature alarm - yellow LED on)
• Allowed duty cycle exceeded
• Connection to ground not carried out correctly
No output power (no
• Mains voltage outside the range of the allowed
welding takes place)
operating voltage (yellow LED on)
• Electronic system defective
• Wrong selection of the welding process
• Wrong parameter setting and functions of the
system
Wrong output power
• Potentiometer / encoder for regulating the
welding current defective
Tab. 12
Troubleshooting
BAL.0323.0 • 2017-08-31
DANGER
(in Germany see TRBS 1203).
(option), wire feeder iROB Feed (option), remote control iROB Control (option) and welding torch.
Solution
• Check the electric system and repair it if necessary
• Replace the defective part
• Have it repaired by the customer service
• Replace the defective part
• Replace the defective part
• Have it repaired by the customer service
• Check robot output for start
• Check robot interface
• Replace the defective part
• Have it repaired by the customer service
• Wait for the system to cool down, do not switch off
the system!
• Make sure that the connection to ground is correct
 6 Putting into operation on page EN-13
• Bring mains voltage again inside the range of the
allowed operating voltage of the power source
• Establish proper connection
 7 Operation on page EN-17
• Have it repaired by the customer service
• Select the correct welding process
• Set the welding parameters correctly
• Replace the defective part
• Have it repaired by the customer service