Rv53I; Specifications - Rinnai RV53i Manuel D'installation Et D'utilisation

Chauffe-eau d'intérieur sans réservoir à ventilation directe
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model
Minimum Gas Consumption Btu/h
Maximum Gas Consumption Btu/h
Hot water capacity (Min - Max) *
Hot water capacity (45°F rise)
Temperature Settings (without temperature
controller)
Temperature Controller Default Setting
Maximum Temp Setting (residential)
see Temperature Ranges for more information
Minimum Temperature Setting
Weight
Energy Factor
Noise level
Normal
Electrical Consumption
Standby
Anti-frost Protection
By-Pass Control
Natural Gas
Minimum Gas Supply
Pressure
Propane
Natural Gas
Maximum Gas Supply
Pressure
Propane
Type of Appliance
Operation
Approved Gas Type
Connections
Ignition System
Electric Connections
Water Temperature Control
Water Supply Pressure
Maximum Water Supply Pressure
Remote Control Cable
Energy Star Qualified
Certified for installation in manufactured
(mobile) homes
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.

Specifications

RV53i

15,000
150,000
5.3 GPM (20.0 L/min)
51 lb (23.0 kg)
55 W
184 W
Temperature controlled continuous flow gas hot water system.
With or without temperature controller, mounted in kitchen, bathroom, etc.
Natural Gas or Propane - Ensure unit matches gas type supplied at the installation location.
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)
RV53i & RV53e Operation and Installation Manual
0.6 - 5.3 GPM (2.4 - 20.0 L/min)
120º F (49º C), default or 140º F (60º C)
104º F (40º C)
140º F (60º C)
98º F (37º C)
0.82
49 dB
2 W
Fixed
5.0 inch W.C.
8.0 inch W.C.
10.5 inch W.C.
13.5 inch W.C.
Direct Electronic Ignition
Simulation Feedforward and Feedback.
150 PSI
Non-Polarized Two Core Cable (Minimum 22 AWG)
Yes
Yes
RV53e
20,200 (LP)
19,000 (NG)
120,000
4.2 GPM (16.0 L/min)
34.2 lb (15.5 kg)
0.82
33 W
74W
3

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Rv53eReu-vb2020ffu-usReu-vam1620w-us