Télécharger Imprimer la page

BFT MOOVI 30 - ALPHA BOM Instructions D'utilisation Et D'installation page 18

Masquer les pouces Voir aussi pour MOOVI 30 - ALPHA BOM:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
INSTALLATION MANUAL
;;
8'
;;
o
;::
;!
:xi
o
17.2) TABLE A: DIP SWITCH
Cross out
DIP
Default
Definition
setting
Description
used
TCA- Automatic
ON
Automatic
closing ON.
DIP 1
ON
closing time.
OFF
Automatic
closing OFF.
ON
Photocells active during closing only.
DIP 2
ON
FCH- Photocells.
OFF
Photocells active during closing and opening.
ON
STARTcommands
not accepted during opening.
DIP 3
OFF
BLI - Block Pulses.
OFF
STARTcommands
accepted during opening.
3P/4P - 3 steps or 4
ON
Switches to 3-step logic.
DIP 4
OFF
steps.
OFF
Switches to 4-step logic.
ON
Activates built-in
receiver in fixed-code
mode.
DIP 5
OFF
CODE FIX - Fixed code.
OFF
Activates built-in
receiver in rolling-code
mode.
RADIO LEARN -
ON
Enables wireless memorizing
of transmitters
(Sect. "Remote Programming").
DIP 6
OFF
Transmitter
program-
Disables wireless memorizing
of transmitters.
Transmitters
are memorized
only by means of
mingo
OFF
manual programming.
SCA- Gate open light
ON
Activates relay output
as 2nd radio channel.
DIP 7
OFF
or 2nd radio channel.
OFF
Activates relay output
in Gate open light mode.
ON
Closes barrier after the photocells
are cleared before waiting for the setTCA to elapse.
DIP 8
OFF
FAST CLOSE
OFF
Command
not enabled.
1 8 -
MOOV130-50
- ALPHA 80M

Publicité

loading

Ce manuel est également adapté pour:

Moovi 50 - alpha bom