Adjustments; Manual Release; Test Photoelectric Sensors - CAME FE4024 Instructions D'installation

Masquer les pouces Voir aussi pour FE4024:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ADJUSTMENTS

MANUAL RELEASE

The manual release allows you to manually open or close the gate. Manual release
operations need to be carried out during emergency procedures and with the power
disconnected.
Open the door with the customized key. To release the gearmotor, rotate the release
lever fully clockwise. To lock the gearmotor, rotate the release lever back to the
original position.

TEST PHOTOELECTRIC SENSORS

Each open/close command, the electronic card verifies the photoelectric
sensors are connected and working. Any problems with the photoelectric
sensors will cause the (PROG) LED to flash on the electronic card, which
cancels any commands from the remote control or push-button.
1
Electrical connection to operate the photoelectric sensors safety test:
• Connect the transmitter and receiver as shown in the diagram.
2
From the functions menu, select "Safety Tests" and select either CX - CY - CZ
inputs to activate the test.
After all adjustments have been completed, attach the cover to the
operator with the provided screws.
Left-Hand Installation
RELEASE
LOCKING
MANUAL RELEASE + TEST PHOTOELECTRIC SENSORS
Right-Hand Installation
LOCKING
DIR10 Photoelectric Sensors:
27
RELEASE

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Fe4024v

Table des Matières