WIRING
WIRE THE ENTRAPMENT PROTECTION DEVICES
WIRE THE ENTRAPMENT PROTECTION
DEVICES
Two-wire normally open edge
Wireless Communicator
EDGE SENSORS (CONTACT)
An entrapment protection devices such as photoelectric sensors or an edge MUST be
Receiver
wired to the operator and then configured for your application using the
PWR
Relay
programming menu. Refer to page 21- page 26 for programming information.
Transmitter
Input for UL325 compliant entrapment protection devices such as edge sensors.
24V C
C NO NC
Configure either CX, CY, or CZ (N.C.) contacts.
C7 "OPEN WHILE CLOSING" (N.C.) Contact
This input functions to reverse the gate to the open limit when activated during the
close cycle.
NOTE: If not used, deactivate.
C8 "CLOSE WHILE OPENING" (N.C.) Contact
This input functions to reverse the gate to the close limit when the edge is activated
during the opening cycle.
NOTE: If not used, deactivate.