VISIOMED ThermoFlash LX-26E Manuel D'utilisation page 63

Masquer les pouces Voir aussi pour ThermoFlash LX-26E:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 4
EMC data
Guidance and manufacturer's declaration - electromagnetic
immunity - for equipement and system that are not life-
supporting. The model LX-26E is intended for use in the
electromagnetic environment specified below. The customer or
the user of the model LX-26E should assure that it is used
in such an environment.
EN
Immunity
60601
Compliance
test
test
level
level
Conducted
3 Vrms
N/A
RF
150 kHz
IEC
to 80
61000-4-6
MHz
Radiated
3 V/m
3 V/m
RF
80 MHz
IEC
to 2.5
61000-4-3
GHz
Note 1: At 80 MHz and 800 MHz, the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electro-
magnetic is affected by absorption and reflection from structures,
objects and people.
a. Fields strengths from fixed transmitters, such as base stations for
radio (cellular/cordless) telephones and land mobile radios, ama-
teur radio, AM and FM radio broadcast and TV broadcast cannot be
predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site
124
Visiomed - LX-26E - 092014
11111111111111111111
Electromagnetic
environment - guidance
Portable and mobile RF communica-
tions equipment should be used no
closer to any part of the model LX-26E,
including cables, than the recom-
mended separation distance calcu-
lated from the equation applicable to
the frequency of the transmitter.
Recommended separation distance
[ 3.5
d =
] √
80 MHz to 800 MHz
P
E1
[ 7
] √
d =
P
800 MHz to 2.5 GHz
E1
where P is the maximum output
power rating of the transmitter in
watts (W) according to the transmit-
ter manufacturer and d is the recom-
mended separation distance in meters
(m).b
Fields strengths from fixed RF transmit-
ters, as determined by an electromag-
netic site survey, a should be less than
the compliance level in each frequency
range.b
Interference may occur in the vicinity of
equipment marqued with the following
symbol:
survey should be considered. If the measured field strength in the
location in which the model LX-26E is used exceeds the applicable
RF compliance level above. The model LX-26E should be observed to
verify normal operation. If abnormal performance is observed, addi-
tional measures may be necessary such as reorienting or relocating
the model LX-26E.
b. Over the frequency range 150 kHz to 80 MHz, field strengths
should be less than 3V/m.
Recommended separation distances between portable and mo-
bile RF communications equipment and the equipment or system
- for equipement and systems that are not life-supporting. The
model LX- 26E is intended for use in an electromagnetic environ-
ment in which radiated RF disturbances are controlled. The custo-
mer or the user of the model LX-26E can help prevent electroma-
gnetic interference by maintaining a minimum distance between
portable and mobile RF communications equipment (transmitters)
and the model LX-26E as recommended below, according to the
maximum output power of the communications equipment.
Rated maximum
output
of transmitter
80 MHz to 800 MHz
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above
the recommended separation distance d in meters (m) can be esti-
mated using the equation applicable to the frequency of the trans-
mitter, where P is the maximum output power rating of the trans-
mitter in watts (W) according to the transmitter manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the
higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electro-
magnetic propagations is affected by absorption and reflection
from structures, objects and people.
Visiomed - LX-26E - 092014
Separation distance according to
frequency of transmitter m
800 MHz to 2.5 GHz
[ 3.5
[ 7
d =
] √
d =
P
E1
E1
0.12
0.23
0.38
0.73
1.2
2.3
3.8
7.3
12
23
] √
P
125

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières