6 . Connect t he wiring [ 1 ] t o t he t erm inals according t o t he diagram
on page 2. Wire colours:
x red ( + )
W a rn in g : do not short - circuit any t erm inals.
7 . Connect t he power supply.
8 . To t est t he PI R sensor, set t he light sensit ivit y t o OFF and t he
m ovem ent sensit ivit y and 5" t o ON. The load should swit ch on
im m ediately and – when no m ovem ent is det ect ed – swit ch off
aft er 5 s.
N ot e : DO NOT change t he DI P swit ch set t ings when power is
connect ed!
5 .
Te ch n ica l Sp e cifica t ion s
swit ch t ype
det ect ion angle
det ect ion range
rat ed load
input
out put
working t em perat ure
working hum idit y
t im e- delay swit ch
light cont rol
dim ensions
weight
Use t h is d e v ice w it h orig in a l a cce ssor ie s on ly . Ve lle m a n n v
ca n n ot b e h e ld re sp on sib le in t he e v e nt of d a m ag e or in j u ry
re su lt in g from ( in cor re ct ) u se of t h is d e v ice . For m ore in fo
con ce rn in g t h is p rod u ct a n d t he la t e st v e rsion of t h is m a n u a l,
p le a se v isit ou r w e b sit e w w w .v e lle m a n. e u . Th e inform a t ion in
t h is m a n u a l is su b j e ct t o ch a n g e w it h ou t p rior n ot ice .
V. 04 – 17/ 10/ 2014
PI R4 1 6
y black ( -)
relay
100°
8 m ( @ 22 ° C)
25 W resist ive load
( m ax. inrush current 2. 1A)
12 Vdc, 2. 6 A
m ax. 12 Vdc 2. 5 A / 25 W
- 10 ° C t o + 40 ° C
< 93 % RH
5 s, 30 s, 1 m in, 3 m in, 5 m in, 8 m in
< 3 lx t o 2000 lx
visible part
hidden part ( cont roller) 55 x 25 x 35 m m
± 41 g
5
z brown
Ø 22 x 1 0 m m
© Vellem an nv