Troubleshooting
Fault
The display does not
respond to keystrokes.
The app cannot
control the device.
The display shows an
alert message or
warning code.
Alert messages
fig. o A, page 16.
E.g. see
Alert message
Description
!ALERT - Lid open
Lid open more
> 3 min
than 3 minutes
!ALERT - Voltage
The device has
low
stopped working
on DC due to low
voltage
The device has
stopped working
on DC due to
abnormally high
voltage >31.5 V
(unlikely event –
for electronics
protection only –
uses same alert
message as low
voltage above)
36
Possible cause
The display is locked.
Bluetooth or WiFi is not
connected.
Possible cause
Lid not fully
latched
Internal fault
Insufficient supply
voltage
Battery voltage is
too low
Battery protec-
tion is set too high
Wrong DC supply
voltage
specification
Faulty supply
voltage
Internal fault
Suggested remedy
Unlock the display, see chapter "Lock-
ing/unlocking the display" on page 29.
Connect Bluetooth, see chapter "Set-
ting the Bluetooth signal and connecting
to the app" on page 32, or Connect
WiFi, see chapter "Setting the WiFi sig-
nal and connecting to the app" on
page 32.
See table below.
Suggested remedy
Check lid latched fully
Authorised repair centre
inspection required
Check voltage drop
from battery to power
outlet and increase wir-
ing gauge if necessary
Test the battery and
charge as needed
Select a lower battery
protection setting
Ensure DC supply
voltage specification
matches CFX3 product
rating label
Check DC voltage
supply & repair or
replace if faulty
Authorised repair centre
inspection required