TROUBLESHOOTING

TROUBLE
The motors do not work; no warning light turns on.
The machine does not move and the display (71)
shows the error code:
At the machine start-up, the LED (64) of the
switch (63) flashes and the brushes do not work.
The brushes do not work; the red warning light
flashes.
The 3 warning lights (62) flash simultaneously.
The display (71) shows an error code as:
where "00" is replaced by a code different from
"t4".
The dirty water vacuuming is insufficient.
The solution flow is insufficient.
The squeegee leaves marks on the floor.
NOTE
If the machine has a battery charger installed, the machine cannot operate if the charger is not on board. In case of
battery charger malfunction, contact an authorised Service Center.
For further information, contact Nilfisk Service Centers.
9098960000(2)04/2016 A
POSSIBLE CAUSE
The battery connector is disconnected.
The batteries are discharged.
The machine has been turned on by using the
ignition key and by keeping the pedal pressed.
The machine has been turned off without
lifting the brush deck.
The batteries are discharged.
The brush motors are overloaded.
There are foreign materials (tangled threads,
etc.) preventing the brushes from rotating.
The machine electronic control system is in
alarm condition.
The recovery tank is full.
The vacuum grid is clogged or the float is
closing.
The container with debris collection grid is
clogged.
The hose is disconnected from the squeegee. Connect.
The squeegee is dirty, or the squeegee blades
are worn or damaged.
The tank cover is not properly closed, or the
gasket is damaged.
The solution tank is empty.
The solution filter is dirty.
The Chemical Mixing System tank (optional)
is dirty/clogged.
There are debris under the squeegee blades.
The squeegee blades are worn, chipped or
torn.
The squeegee is not balanced with the
handwheel.
SCRUBTEC R 466 - R 471 - R 471C - BOOST
USER MANUAL
REMEDY
Connect.
Charge the batteries.
Release the drive pedal.
If the problem persists, contact an authorised
Service Center.
Wait for the deck to lift before turning on again
the brushes by pressing the switch.
Charge the batteries.
Use less aggressive brushes and/or avoid
working with extra pressure turned on.
Clean the brush hubs.
Turn off the machine and then turn it on again.
If the problem persists, contact an authorised
Service Center.
Empty the tank.
Clean the vacuum grid.
Clean.
Clean the squeegee or overturn/replace the
blades.
Correctly close the cover or clean/replace the
gasket.
Refill.
Clean the filter.
Clean with the drain cycle.
Remove the debris.
Overturn or replace the blades.
Adjust the squeegee.
R4
®
ENGLISH
29