17.1.1 Error - Codes

Error Code
Hardware Protection Mode
01
Possible damage to electronic controller
Software Protection Mode
02
Possible damage to electronic controller
software
Low Voltage Abnormality
Protection Mode
03
Voltage is lower than 165V
Spindle Direction Protection
Mode
06
The spindle direction has been changed
High Voltage Abnormality
07
Protection Mode
Voltage is higher than 265V
Motor Speed Protection Mode
08
Motor speed has been increased sharply,
indicating possible user error.
MANY POTENTIAL SOURCES OF ERROR CAN BE CLEARED BY THE EXPERTLY CONNECTION TO
THE ELECTRICITY GRID.
HOLZMANN MASCHINEN GmbH
ERROR - CODES
Error
during operation
www.holzmann-maschinen.at
Solution
 Turn off the machine and re-start once the
digital display has cleared.
 If error code still appears the controller
hardware may be damaged and customer
services should be contacted.
Turn off the machine and re-start once the
digital display has cleared. If error code still
appears the controller software may be damaged
and customer services should be contacted.
 It is normal for this error code to appear for a
short period after turning the machine off.
 If it appears during operation, turn off the
machine and re-start once the digital display
has cleared.
 If error code is still shown the power supply
must be checked and corrected if neccesary.
Turn off the machine and re-start once the
digital display has cleared.
Turn off and and re-start the machine. If error
code still appears, check and correct the power
supply.
Turn off the machine and re-start. If error code
still appears, the motor of controller may be
damaged.
TROUBLESHOOTING